← All publications
Conference 2012

An Empiric Evaluation of Confirmation Methods for Optical See-Through Head-Mounted Display Calibration

P. Maier , A. Dey , C. A. L. Waechter , C. Sandor , M. Tönnis , G. Klinker

ICAT/EGVE/EuroVR

Calibrating optical see-through headsets requires the user to align on-screen points with the real world and confirm each alignment, and the confirmation step itself can introduce error. This paper empirically compares four confirmation methods — keyboard, hand-held, voice, and waiting — using a video see-through display to record ground-truth alignments. The 'waiting' method, designed to reduce head motion, was significantly more accurate than the others, and averaging alignments over a short time window improved every method further.

DOI ↗ Scholar ↗
BibTeX
@inproceedings{maier2012,
  author    = {P. Maier and A. Dey and C. A. L. Waechter and C. Sandor and M. Tönnis and G. Klinker},
  title     = {An Empiric Evaluation of Confirmation Methods for Optical See-Through Head-Mounted Display Calibration},
  booktitle = {ICAT/EGVE/EuroVR},
  pages     = {73-80},
  doi       = {10.2312/EGVE/JVRC12/073-080},
  year      = {2012}
}